1
If the high voltage circuit is disconnected like this, a long arc will form between the contact and the contact point, and the arc temperature can reach 8000 degrees Celsius,
2
causing the contact point to start melting, and the circuit unable to be completely disconnected.
3
To solve this problem engineers invented the sulfur hexafluoride circuit breaker.
4
Let's see how it works.
5
The upper part of the circuit breaker is connected to one end of the transmission line, the middle part is connected to the other end of the transmission line, and the lower part is connected to the controller of the
6
circuit breaker through a mechanical device its upper part is made of copper.
7
And the fixed lower part on the street is also made of copper, but it is hollow and can be moved to connect with the upper contact to complete the circuit.
8
The issue is how the lower contact can move upwards.
9
This is where the mechanical controller at the bottom comes into play.
10
The controller has two springs underneath, already in a compressed state.
11
There is a plunger system here, connected to a relay and firmly pressing against the latch.
12
Near the circuit breaker, there are also some current transformers.
13
When there is a problem in the circuit, the current in the transformers increases, and they send the abnormal situation to the relay.
14
This is when the plunger of the relay extends outward, releasing the latch.
15
At this point, the spring on the left will release its tension, then quickly pull down, connecting to the lever on the spring, which is connected to the small gear at this position,
16
causing the shaft to rotate rapidly, with the shaft simultaneously connected to three circuit breakers.
17
Take a closer look at the cylinder of this joint, it is actually filled with sulfur hexafluoride gas, which, when the shaft rotates, will move the lower contact downward,
18
generating a very powerful arc, when the upper and lower contacts disconnect as before.
19
Due to the downward movement of the piston, the pressure of sulfur hexafluoride gas increases, causing sulfur hexafluoride to move upwards, completely extinguishing the arc between the two contact points.
20
How does sulfur hexafluoride extinguish the arc?
21
Sulfur hexafluoride is able to extinguish the arc because high temperatures cause it to ionize into negative ions, which prevent free electrons from moving and thus eliminate the arc.
22
However, there is an issue.
23
After the arc is extinguished, the temperature inside the circuit breaker decreases, and under certain pressure, sulfur hexafluoride will transform into a liquid.
24
At this position, a heater is also needed to ensure that SF6 remains in a gaseous state.
25
Of course SF6 will also be consumed, so a pressure gauge is installed at the top of the circuit breaker to replenish the gas once the pressure drops.
26
Additionally, for added safety measures, all these contacts need to be opened to achieve double security
27
here is an issue suddenly disconnecting the high voltage transmission line
28
will cause a current search since transformers are usually connected behind
29
the circuit breaker the sudden return of a powerful current can lead to voltage instability even damaging the transformer
30
so unless there is a major accident high voltage transmission lines are generally not disconnected
31
so how do you reconnect the transmission line now let's go
32
back to the circuit breaker in fact there is also a
33
relay on the right side here with a mechanical design identical to the one on the left.
34
When the relay receives a signal from the control panel, the plunger of the relay triggers the latch, which, when released, under the action of the spring, will start the rotation of the gear above,
35
pulling up the lever on the left and compressing the spring on the left.
36
Causes piston of circuit breaker to move up, connecting entire transmission line.
37
However there's an issue, pressure of spring on right side already released, so how to reset it?
38
Actually it's simple, electric motor behind circuit breaker.
39
When circuit breaker closes, electric motor will drive gears to rotate, resetting spring on right side.
40
at ACE, where technology meets sustainability.

Télécharger l'application

Tout pour parler couramment

Prononciation IAChaque phrase notée
Phonétique (IPA)Maîtrisez chaque son
VocabulaireEnrichissez votre lexique
Jeu de vocabulaireApprenez en jouant
FOR YOU

Vidéo recommandée

Vocabulaire et conseils d’expression pour cette leçon

Cette leçon d’expression orale s’appuie sur la vidéo « Inside the Relay Controlled SF6 Circuit Breaker: Preventing Arcs and Ensuring Safety ». Les mots qui reviennent le plus souvent : circuit, breaker, contact, arc, hexafluoride. Cette vidéo contient 40 phrases et 688 mots à répéter en shadowing. La partie parlée dure 3:54. Le locuteur parle à un rythme naturel d’environ 176 mots par minute, proche d’une conversation courante. Seuls 73 % des mots font partie des 3 000 mots les plus courants en anglais, le vocabulaire est donc exigeant.

Vocabulaire clé de cette vidéo

15 mots de la vidéo à retenir, avec leur prononciation et leur sens :

MotPrononciationSens
breaker nom/ˈbɹeɪkɚ/casseur
connect verbe/kəˈnɛkt/accoupler, connecter
transmission nom/tɹænsˈmɪʃən/transmission
voltage nom/ˈvəʊltɪd͡ʒ/tension, voltage
gear nom/ɡɪɚ/panoplie, matériel
mechanical adjectif/məˈkænəkəl/mécanique
controller nom/kənˈtɹoʊlɚ/contrôleur, manette
shaft nom/ˈʃɑːft/hampe
rotate verbe/ˈɹoʊ.teɪt/tourner, rotationner
copper nom/ˈkɒpə/cuivre
reset verbe/ɹiːˈsɛt/remettre à zéro, réinitialiser
upwards adverbe/ˈʌpwɚdz/en haut
lever nom/ˈliː.və/levier
solve verbe/sɒlv/résoudre, régler
sudden adjectif/ˈsʌd.ən/soudain, subit

Les verbes à particule que vous entendrez

MotPrononciationSens
pull down verberabattre, ramener
pull up verbe/ˌpʊl ˈʌp/soulever

Prononciation à surveiller

  • Les sons « sh » et « zh »: transmission /tɹænsˈmɪʃən/, shaft /ˈʃɑːft/, tension /ˈtɛnʃən/, rotation /ɹoʊˈteɪʃən/, extinguish /ɪkˈstɪŋ.ɡwɪʃ/
  • Mots longs — placez bien l’accent: mechanical /məˈkænəkəl/, simultaneously /ˌsaɪmlˈteɪnɪəsli/, eliminate /ɪˈlɪm.ɪ.neɪt/, sustainability /səˌsteɪnəˈbɪlɪti/, instability /ɪnstəˈbɪlɪti/

Les sons difficiles pour les francophones :

  • /h/ — il se souffle, il n’est pas muet: hollow /ˈhɑloʊ/, heater /ˈhitɚ/
  • /tʃ/ et /dʒ/ — à ne pas adoucir en « ch » et « j »: voltage /ˈvəʊltɪd͡ʒ/, generate /ˈd͡ʒɛn.ə.ɹeɪt/, gauge /ˈɡeɪd͡ʒ/, latch /læt͡ʃ/, plunger /ˈplʌnd͡ʒɚ/
  • /r/ anglais — langue recourbée, sans frotter la gorge: breaker /ˈbɹeɪkɚ/, transmission /tɹænsˈmɪʃən/, relay /ˌɹiˈleɪ/, controller /kənˈtɹoʊlɚ/, rotate /ˈɹoʊ.teɪt/

Comment s’entraîner avec cette vidéo

  1. Écoutez la vidéo en entier une fois sans parler et notez les mots que vous ne connaissez pas.
  2. Commencez à la vitesse 0,75×, répétez phrase par phrase, puis revenez à la vitesse normale quand cela devient facile.
  3. Enregistrez-vous et comparez avec l’original, en faisant attention à des mots comme breaker, connect, transmission.

Qu'est-ce que la technique du Shadowing ?

Le Shadowing est une technique d'apprentissage des langues fondée sur la science, développée à l'origine pour la formation des interprètes professionnels. Le principe est simple mais puissant : vous écoutez de l'anglais natif et le répétez immédiatement à voix haute — comme une ombre suivant le locuteur avec un décalage de 1 à 2 secondes. Les recherches montrent une amélioration significative de la précision de la prononciation, de l'intonation, du rythme, des liaisons, de la compréhension orale et de la fluidité.

Technique du shadowing : lire le guide complet étape par étape →