Hey there guys, Paul here from TheEngineeringMindset .com.
2
In this video, we're going to be looking at a typical single -phase electricity supplier into a domestic property.
3
We're going to look at the distribution cables and transformer, the phase neutral on earth, the main fuse, the electricity meter,
4
the isolation switch, the consumer unit as well as the RCDs and MCBs.
5
Now, this is a common design used across the UK, Europe, India, Australia, New Zealand, etc. There are some slight variations,
6
and these components may look a little different between the countries, but essentially it's very similar.
7
However, North America is a little different because they use two voltages in the homes,
8
so we're going to look at that in detail in a separate video.
9
You can still follow along in this video to understand the basics, though.
10
I'm going to be using the European color codes for this video that may be different from your local regulations.
11
Remember, electricity is dangerous and can be fatal.
12
You should be qualified and competent to carry out any electrical work.
13
So the electricity is generated far away at the power station.
14
The electricity leaves the power station
15
and the voltage is increased in a step -up transformer where it will then be distributed over long distance transmission lines.
16
We generate and distribute AC alternating current because it is more efficient and convenient than DC direct current.
17
Once it reaches the town, the voltage will be reduced in a substation step -down transformer.
18
If you want to learn how transformers work, we've covered this in a previous video, do check that out, links in the video description below.
19
From the substation, the electricity will either be distributed locally through overhead or underground cables.
20
Depending on the local design and the voltages being used, a home might be connected directly to a small transformer located close to the property
21
or alternatively a group of houses will share a larger transformer.
22
The electricity is distributed in three phases
23
but in this case we're looking at a single phase installation
24
which means the property is connected to just one of these three phases as well as the neutral.
25
We've also covered how three -phase electricity works in a previous video do check that out links in the video description below.
26
Now, each house in a street might be alternately connected to a different phase
27
or different streets might be connected to different phases.
28
This is just to try and balance the demand on the transformer.
29
A smaller service cable comes off the distribution cable and will feed the property.
30
This service cable will again be overhead or underground depending on the local installation.
31
The service cable contains the phase and neutral wires.
32
There's also a metal protective sheath around the cable in most cases especially
33
if it's buried underground the service cable comes in the electricity
34
is going to flow through the phase pass through the main fuse then through the electricity meter
35
and then into the consumer unit the service head
36
or cutout holds the main fuse
37
or service fuse this fuse provides protection to the property
38
and ensures only a set amount of current can flow into the property for example in the uk
39
it's typical to have a fuse rated between 60
40
and 100 amps the electricity distribution company may also remove this fuse to isolate the property.
41
They may do this for example to replace the electricity meter.
42
The phase and the neutral then enter the electricity meter which quantifies how much energy is being consumed.
43
You may find that this meter is mechanical or electrical or even a digital smart meter.
44
There are a lot of variations of design for these.
45
The phase and the neutral will then leave the electricity meter and enter the consumer unit or fuse board.
46
The The consumer unit or fuse board varies in size depending on the size of the property
47
and how many circuits there are being controlled.
48
Inside the consumer unit we first have the main switch or main double pole isolation switch.
49
This controls the supply of electricity to the rest of the consumer unit and therefore all the circuits feeding the property.
50
This switch is not automatic and must be manually flipped to cut the power.
51
This switch will disconnect both the phase and the neutral line together.
52
The cables typically enter the main switch via the top terminals.
53
At the bottom we find the neutral wire which will connect to the neutral block connection.
54
We might find one or more phase wires coming out of the bottom of the main switch to feed the RCDs.
55
If there aren't RCDs being used, then a bus bar will feed the circuit breakers but we'll look at that again shortly.
56
The phase line enters the RCD or residual current device, again usually entering via the top.
57
This RCD switch is constantly monitoring the electrical current.
58
It's checking if the current in the phase line is equal to the current in the neutral line.
59
If these two currents are not equal,
60
then there is an electrical fault and the device will quickly and automatically cut the power to everything past the switch.
61
Typically, an RCD will break the circuit
62
if it measures a difference of 30 milliamps as anything above this is dangerous for humans.
63
If you touch a live wire and electricity flows through you to the ground,
64
then the current is bypassing the neutral wire so the phase and the neutral currents will not be equal.
65
The RCD will notice this and then cut the circuit to reduce the risk of electric shock or death.
66
It's now increasingly common to have two or more RCDs in a consumer unit.
67
In such case, the RCD will only cut the power to the circuits connected directly after it.
68
So the other RCD will still be powered and only some parts of the property will lose power.
69
The RCD will trip when it believes the current is unsafe even for a fraction of a second.
70
It does need to be manually reset to restore the power,
71
but this does not solve the problem and you should locate and remove any faulty appliance or fixture.
72
From the bottom of the RCD, we have a buzz bar.
73
This is just some conductive metal which the electricity flows along and connects into each of the MCBs,
74
which just makes the installation easier rather than having a lot of cables.
75
The MCB or miniature circuit breaker controls individual smaller circuits.
76
For example, connected to one RCD, maybe we'll have one MCB for the downstairs lighting, one for the upstairs lighting,
77
and one for the kitchen plug sockets.
78
On the other RCD, maybe we have one for the stairwell lighting, one for the upstairs lighting, and one for the downstairs plug sockets.
79
These switches will quickly and automatically trip to cut the power, but they also need to be manually set to restore the power.
80
The MCB protects the circuit in two ways, overload and short circuit.
81
The MCB is rated to handle a certain amount of current passing through it.
82
For example, 32 amps for the plug sockets.
83
If this value is exceeded on that circuit, for example, by gradually plugging in too many things,
84
then the MCB will trip and cut the power to protect itself.
85
The other protection it offers is short circuit protection.
86
In the event of a short circuit, for example, the live touches the neutral,
87
then the circuit is bypassed and there may be a large and instantaneous increase in current.
88
This will create a magnetic field inside the MCB which will cut the power to protect itself.
89
The phase then leaves via the top of the MCB and will flow through the circuit, for example through some lamps.
90
It then returns via the neutral cable and into the neutral block.
91
All the circuits do this with the phase coming out of the circuit breaker
92
and heading off around the property and the neutral lines coming back and meeting at the neutral block.
93
The neutral block is then connected to the RCD which checks
94
if the current flowing in is equal to the current flowing out.
95
The neutral then flows from the RCD to the main neutral block
96
and from there back to the main switch which is connected to the electricity meter and the service head.
97
So electricity can then flow from the main distribution phase line up through the service head and the main fuse.
98
It then flows through the electricity meter and into the consumer unit main switch.
99
From the main switch it flows through the the RCD, along the buzz bar and into the MCB.
100
It then flows up around the MCB separated circuits.
101
The electricity can then come back via the neutral lines and into the neutral blocks.
102
It then flows through the RCD and back into the main block.
103
From there, back into the main switch and then the electricity meter.
104
It will then pass through the service head and the fuse and back into the neutral line of the main distribution cables.
105
Now you may have noticed that there's some other cables with green and yellow stripes.
106
These are called the IRF cables.
107
This IRF cable usually runs along with the phaser neutral wires into the fixtures such as light switches and plug sockets.
108
Some appliances will also use an IRF wire for added protection, typically if the device uses a metal casing.
109
The IRF wires will connect from these fixtures into the neutral block with the consumer unit.
110
All the IRF cables for each circuit then connect into the IRFing block in the unit.
111
Another IRF cable will then connect from this IRFing block in the consumer unit over to the main protective earthing terminal,
112
which is typically located somewhere near the electricity meter.
113
Other earthing wires will connect from this main earthing terminal over
114
and onto metal pipes such as the plumbing and the gas pipework.
115
That way, if a person touches a live wire in a metal pipe in the property,
116
the electricity will flow through the earth wire and should be detected by the RCD, which will cut the power.
117
There are a few ways the main protective earthing terminal is connected to ground.
118
The first option is shown here, with the main earth terminal being connected to the neutral wire of the service cable within the service head.
119
This means that the phase to earth fault is effectively now a phase to neutral fault instead.
120
Another option is to use the metal protection sheath around the service cable as the earth conductor.
121
So the main earth terminal is connected to the metal sheath
122
and this carries the phase to earth fault back to the transformer.
123
The other option, which is when the electricity supplied doesn't provide an earth path
124
so instead the main earth terminal is connected to an electrode rod
125
which is installed into the ground and provides a direct earth path.
126
Okay that's it for this video but
127
if you want to continue your learning then check out one of the videos on screen now
128
and I'll catch you there for the next lesson.
129
Don't forget to follow us on Facebook, Twitter, Instagram and of course theengineeringmindset .com.

アプリをダウンロード

流暢に話すために必要なすべて

AI発音採点文ごとに採点
IPA練習すべての音をマスター
単語学習自分の単語帳を作る
単語ゲーム遊びながら覚える

同じチャンネル

FOR YOU

おすすめ動画

このレッスンの語彙とスピーキングのポイント

このスピーキングレッスンは、動画「Single Phase Electricity Explained - wiring diagram energy meter」を教材にしています。 繰り返し出てくる語は次のとおりです:neutral, electricity, phase, main, Rcd。 この動画には、シャドーイング用の文が129文、単語が1885語あります。 音声の長さは9:58です。 話す速さは速く、1分あたり約189語です。音のつながりや弱く発音される音が多くなります。 英語の頻出3,000語に含まれる単語は79%だけなので、語彙は難しめです。

この動画の重要語彙

動画に出てくる覚えておきたい単語15語を、発音と意味つきで紹介します。

単語発音意味
neutral 形容詞/ˈnuː.tɹəl/中立の
connect 動詞/kəˈnɛkt/繋げる
wire 名詞/ˈwaɪɚ/針金, 線
metre 名詞/ˈmiːtəɹ/メートル, ㍍
fuse 名詞/fjuːz/導火線
terminal 名詞/ˈtɚmɪnəl/ターミナル, エアターミナル
plug 名詞/plʌɡ/プラグ
voltage 名詞/ˈvəʊltɪd͡ʒ/電圧
distribute 動詞/dɪˈstɹɪbjuːt/分ける
socket 名詞/ˈsɑkɪt/コンセント
underground 形容詞/ˌʌn.dəɹˈɡɹaʊnd/地下
depend 動詞/dɪˈpɛnd/依存する
installation 名詞/ˌɪn.stəˈleɪ.ʃən/インストール, 取り付け
breaker 名詞/ˈbɹeɪkɚ/破壊者
pipe 名詞/ˈpaɪp/笛

動画に出てくる句動詞

単語発音意味
come back 動詞戻る, 帰る
carry out 動詞/ˈkæ.ɹi aʊt/行う, 実行する
check out 動詞試験する, 検査する

この動画の文法

話し手がよく使っている文型を、動画の実際の表現とともに紹介します。

文型動画での表現
受動態 be + 過去分詞 — 誰がするかより、何が起きるかに焦点を当てるis generated · is increased · will be reduced
関係詞節 who / which + 節 — 人や物について情報を加えるwire which will · MCB which will · switch which is
現在完了形 have/has + 過去分詞 — 過去の出来事が今も関係しているwe've covered · We've also covered

注意したい発音

話し手はwe're, we'll, we'veなど、短縮形や弱形を13回使っています。聞こえたとおりの短い形で発音しましょう。

  • 「sh」と「zh」の音: installation /ˌɪn.stəˈleɪ.ʃən/, variation /ˌvɛəɹiˈeɪʃn̩/, isolation /ˌaɪsəˈleɪʃən/, shortly /ˈʃɔɹtli/, shock /ʃɔk/
  • 長い単語(アクセントの位置に注意): electricity /ɪˌlɛkˈtɹɪsɪti/, electrical /ɪˈlɛktɹɪkəl/, installation /ˌɪn.stəˈleɪ.ʃən/, manually /ˈmænj(u)əliː/, isolation /ˌaɪsəˈleɪʃən/

日本語話者が苦手な音:

  • /r/ と /l/ の区別 — /l/ は舌先を歯茎につけ、/r/ はどこにもつけない: neutral /ˈnuː.tɹəl/, electricity /ɪˌlɛkˈtɹɪsɪti/, electrical /ɪˈlɛktɹɪkəl/, shortly /ˈʃɔɹtli/, regulation /ˌɹɛɡjʊˈleɪʃən/
  • /v/ — /b/ にならないように、上の歯を下唇に当てる: voltage /ˈvəʊltɪd͡ʒ/, protective /pɹəˈtɛk.tɪv/, variation /ˌvɛəɹiˈeɪʃn̩/, overhead /ˈəʊvəˌhɛd/, solve /sɒlv/
  • /f/ — 「フ」ではなく、上の歯と下唇で出す: fuse /fjuːz/, fixture /ˈfɪks.t͡ʃə/, leaf /lif/, efficient /ɪˈfɪʃənt/, flip /flɪp/

この動画での練習方法

  1. まず声を出さずに動画を最後まで聞き、知らない単語をメモします。
  2. まず0.75倍速で一文ずつシャドーイングし、慣れてきたら通常の速度に戻します。
  3. 自分の声を録音して元の音声と比べます。neutral, connect, wireなどの単語に特に注意しましょう。

シャドーイングとは?英語上達に効果的な理由

シャドーイング(Shadowing)は、もともとプロの通訳者養成プログラムで開発された言語学習法で、多言語習得者として知られるDr. Alexander Arguelles によって広く普及されました。方法はシンプルですが非常に効果的:ネイティブスピーカーの英語を聞きながら、1〜2秒の遅延で声に出してすぐに繰り返す——まるで「影(shadow)」のように話者を追いかけます。文法ドリルや受動的なリスニングと異なり、シャドーイングは脳と口の筋肉が同時にリアルタイムで英語を処理・再現することを強制します。研究により、発音精度、抑揚、リズム、連音、リスニング力、そして会話の流暢さが大幅に向上することが確認されています。IELTSスピーキング対策や自然な英語コミュニケーションを目指す方に特におすすめです。

シャドーイングのやり方: ステップ別の完全ガイドを読む →