In this video, we will discuss challenges and difficulty we faced during one of our carotid artery stenting case.
2
Patient is 58 year male,
3
presented with acute onset of mild weakness of left upper and lower limb.
4
He has many risk factors responsible for atherosclerosis like hypertension,
5
hypercholestremia, diabetes and he is a chronic smoker.
6
MRI brain showed abnormal T2 hyperintensity at coronary later displaying diffusion restriction suggestive of acute infarct.
7
This location of infarct suggests deep watershed territory infarct between the perforator arteries and superficial cortical arteries.
8
Right carotid angiography showed near total occlusion of right internal carotid artery with poor intracranial flow
9
and there is retrograde reformation of the ophthalmic artery via middle meningeal artery collaterals.
10
This angiographic findings suggest hemodynamic compromise of right cerebral hemisphere.
11
So we plan for carotid artery stenting under embolic protection device in this case.
12
The procedure could be divided into following steps.
13
Carotid access, measurement and choosing the appropriate carotid stent and filter size,
14
pre-dilatation, embolic filter device deployment, stent deployment and post-dilatation.
15
These are the hardware we used in this case.
16
Safe carotid access is the first step of carotid artery stenting procedure.
17
Always look for unfavorable arch in CT angiography images.
18
We placed 8F short sheet at groin and taken 6F long sheet over diagnostic catheter under fluoroscopy to right common carotid artery.
19
By this technique we could avoid the exchange maneuver.
20
This is the right common carotid artery injection via long sheet.
21
We obtained measurement.
22
Based on our measurement we choose 6 to 8 millimeter tapered stent from abort
23
and we also use a smaller size of available embossed shield.
24
As the stenosis is very tight
25
and crossing profile of filter device is larger we plan to pre-dialect the stenosis using the coronary balloon.
26
We use 1.4 BMW coronary wire and 2.5 mm size of the coronary balloon to dilate the stenosis.
27
There is significant improvement of the lumen after the angioplasty.
28
Now we cross the lesion using O.1.4 bare wire of the filter device.
29
It has a 3 cm distal radio opaque tip which we kept at C1 vertebral level.
30
Now AmboShield filter device is taken over the O14 wire.
31
Filter is deployed at C2 vertebral level.
32
Filter device should be placed in the straight segment of the carotid artery
33
and should be more than 2 cm distal to the distal landing zone of carotid stent.
34
Filter has migrated proximally to the level of stenosis during removal of its delivery catheter.
35
To understand proximal migration of the filter device,
36
we need to know the filter design.
37
Ambushil filter device has umbrella like nylon membrane and nitinol frame.
38
This nylon membrane has multiple micropores to allow the blood perfusion and to trap the embolic material.
39
It has two radiopic markers at the proximal and the distal end.
40
AmboShield filter device is a monoreal system pre-loaded on O14 wire.
41
AmboShield is not fixed on this wire,
42
it is freely movable on this wire and because of this there is a risk of intracranial dislodgement of this filter device.
43
To avoid any intracranial migration of AmboShield filter device,
44
there is a focal step design on the bare wire distal to the filter.
45
This focal step is 019 and which will act as a distal limit of the filter device.
46
So when this distal 019 step at the bare wire is in contact with the distal marker of the filter device,
47
it might drag filter proximally
48
if the bare wire is pulled by mistake during the exchange maneuver and this is exactly what had happened in this case.
49
We gently push the filter device upward using the retrieval catheter.
50
Now stent delivery catheter was taken over O14 bare wire.
51
Distal nose of the stent delivery catheter has further pushed the filter device to the desired location.
52
Precise location of stent was confirmed by guide catheter injection.
53
was deployed and delivery catheter was removed.
54
Check angiography showed residual waste so we performed angioplasty of the residual stenosis using 4.5 mm coronary balloon.
55
Only after angioplasty, there was complete occlusion of internal carotid artery.
56
The possibilities could be that the filter device might have occluded due to the trapped embolic materials
57
or acute distant thrombosis or carotid artery dissection and vasospasm.
58
We immediately checked ACT which was within desired level.
59
We repeated 1000 units of heparin bolus.
60
We gave loading dose of agrastat via guide catheter and started IV infusion.
61
We also performed aspiration of the thrombus using coronary aspiration catheter.
62
After all these efforts, check angiography showed some restoration of the flow in the internal cuted artery and across the filter.
63
So we decided to retrieve the filter device.
64
While retrieving the filter device,
65
we only partially engaged the portion of the filter device inside the retrieval catheter to prevent escape of any trapped emboli.
66
After removing the filter device,
67
complete flow is restored in the internal carotid artery and the stent.
68
Gross examination of the filter device showed trapped embolic materials.
69
So we could conclude
70
that the sudden occlusion of the carotid artery after balloon angioplasty
71
is most likely due to release of lot of embolic materials
72
which were trapped by the filter device and causing the complete flow arrest across the carotid artery.
73
Once we remove this filter device the flow is restored.
74
Final angiogram showed complete revascularization of the internal carotid artery and good restoration of the intracranial circulation.
75
This also imply the importance of use of filter device during carotid artery stenting procedure.

下載應用

流利口語所需的一切

AI 發音評分逐句打分
音標練習掌握每個音
詞彙學習建立你的詞庫
詞彙遊戲邊玩邊學

同頻道

FOR YOU

推薦影片

本課程簡介

在本課程中,學習者將練習與頸動脈支架置入相關的專業英語詞彙和短語。通過觀看醫療影片學習內容,您將能夠提高自己的英語口語能力,尤其是在醫學和健康話題上。同時,通過理解病歷的描述,增強對醫學英語的理解,適合希望提高英語發音的學習者。無論您是在日常交流中應用,還是希望在專業場合使用英語,本課程都將助您一臂之力。

關鍵詞彙與常用短語

  • 頸動脈支架 - Carotid artery stenting
  • 動脈內血栓 - Embolic material
  • 血流動力學 - Hemodynamic compromise
  • 臨床表現 - Acute onset of weakness
  • CT血管造影 - CT angiography
  • 過濾裝置 - Filter device
  • 冠狀動脈 - Coronary artery
  • 血管內治療 - Endovascular procedure

練習技巧

為了在學習中取得最佳效果,您可以嘗試陰影練習(shadowing)。隨著影片的播放,逐漸跟隨語速模仿發音和語調。建議從較慢的速度開始,確保能夠準確跟上,然後逐步適應更快的語調。可以選擇分段方式,先重複短句,再逐漸延長至完整段落。通過反覆練習,您將能夠提升自己的英語口語練習技能,特別是在醫療領域。同時,結合看YouTube學英語的方式,提高您對專業術語的發音和運用。確保在學習中關注重音和節奏,以便達到更自然的發音效果。此外,使用shadowspeaks的技巧,幫助您在強化發音的同時,提升對整個句子的流暢度。

什麼是跟讀法?

跟讀法 (Shadowing) 是一種有科學依據的語言學習技巧,最初開發用於專業口譯員的培訓,並由多語言者Alexander Arguelles博士普及。這個方法簡單而強大:您在聽英語母語原聲的同時立即大聲重複——就像是一個延遲1-2秒緊跟說話者的影子。與被動聽力或語法練習不同,跟讀法強迫您的大腦和口腔肌肉同時處理並模模擬實的講話模式。研究表明它能顯著提高發音準確性,語調,節奏,連讀,聽力理解和口語流利度——使其成為雅思口語備考和真實英語交流最有效的方法之一。

影子跟讀法: 閱讀完整分步指南 →