跟读练习: Introduction to EEG - 通过视频学习英语口语

选择练习模式

每种模式都会打开全屏练习室。

121 句
如果句子过短或过长,请点击 Edit 进行调整。
1
In this video, we will review the basics of the electroencephalogram, or EEG, how it's recorded, and how the results can be used in clinical neurology.
2
We will review several topics briefly during this video.
3
The topics will be reviewed in further detail in subsequent videos for those interested in deeper dives into the world of EEG.
4
We will review some of the basic terminology of EEG, how EEG is recorded, how EEG is displayed for interpretation,
5
some common EEG patterns, and how we can use the results of EEG for making decisions in clinical neurology.
6
First, we will start with the terminology.
7
The system by which EEG electrodes are applied to the head
8
and then displayed on EEG recordings is called the International 1020 system.
9
The International 1020 system is a standard method of measuring the head and placing electrodes.
10
It depends on four main positions on the head that are easily transferable between patients.
11
First is the nasion at the bridge of the nose, then the inion, the bony prominence at the back of the head,
12
and then two preauricular points just anterior to each ear.
13
Consider this diagram of a head looking from the top down.
14
The first measurement that is made is from the nasion to the inion, front to back.
15
This measurement is then divided into 10 and 20 % increments, and this is how the 10 -20 system gets its name.
16
Marks are placed, and then a measurement is made from one preauricular point to the other.
17
Again, this is divided into 10 and 20 % increments, and additional marks are made.
18
Further marks are made around the circumference of the head, and separated by 10 % increments.
19
And then parasagittal measurements are made, separated by 25 % increments.
20
And finally, transverse measurements are made.
21
The intersections of these two lines is where the final electrodes are placed.
22
Once all of these marks have been placed, the electrodes can be applied to the scalp of the patient.
23
The electrodes are labeled, as is shown here.
24
The system is very simple, and each electrode is represented by letters and a number.
25
The numbers indicate the side of the head, so that odd numbers are on the left side, and even numbers are on the right.
26
In general, lower numbers mean that the electrode is closer to the midline,
27
so you can see here that C4 is closer to the midline than T8,
28
and the midline itself is represented by a Z, which stands for zero.
29
The letters are indicators of the position on the head.
30
In this central chain of electrodes, you can see that the F stands for frontal, the C for central, and the P for parietal.
31
EEG is recorded using the technology of the differential amplifier.
32
The differential amplifier takes two electrical inputs and displays the output as the difference between the two inputs.
33
This is particularly useful at recording and displaying very small electrical signals, such as those in EEG.
34
For example, you can see these two waveforms, which are very similar, except for one small difference demonstrated here in red.
35
When these two signals are placed through a differential amplifier, you can see that the output is simply the difference between them,
36
and all of the other commonalities are cancelled out.
37
Another way to think about this is to think about the very common children's game that is seen on restaurant menus.
38
You can see that the picture on the left and the picture on the right are very similar, except for a few small differences indicated here.
39
If we were to consider the picture on the left as input one and the picture on the right as input two,
40
we could put these two quote -unquote signals through a differential amplifier and the output would look like this.
41
This example is a good way of thinking about EEG signals as something
42
that is not absolute but rather the difference between two inputs.
43
EEG can be displayed in different ways which are all known as montages.
44
The most common type of montage is a bipolar montage.
45
Here, I have a picture of the head from the top down.
46
If we display the difference between fp2 and f8 as a single tracing, it would look something like this,
47
and we call this single tracing a channel or derivation.
48
Next, we move posteriorly and look at the difference between f8 and t8 and display this as a different channel.
49
We continue to move posteriorly, and we have a string of recordings from the front of the head to the back that are linked together.
50
This string of recordings is called a chain.
51
In this case, this is the right temporal chain.
52
Several chains can be placed together in a single display, such as this example of an anterior -posterior bipolar montage.
53
This anterior -posterior bipolar montage is laid out as
54
if we are looking at the top of the head of the patient and they are facing to the right.
55
Therefore, we first see the left temporal chain, then the left parasagittal chain, then the midline, then the right parasagittal chain,
56
and then the right temporal chain.
57
At the bottom, we see a single EKG channel as well.
58
Another common type of montage is called a common average reference montage.
59
Here, in a single channel, rather than looking at the difference between two adjacent electrodes, as in a bipolar montage,
60
we look at the difference between an electrode of interest and an average of the signals of the rest of the head.
61
Here we can see the layout of an average reference montage,
62
which is very similar, but again we are comparing each channel to an average of the rest of the head.
63
Some relative strengths and weaknesses of different montages are reviewed in a separate video.
64
I will briefly review some commonly encountered EEG patterns, simply to whet your appetite for further EEG learning.
65
One of the most commonly encountered entities on an EEG recording is an eye blink, and so I will review this briefly.
66
We have to think about the eye as a dipole with a polarity.
67
There is the retina and the cornea.
68
The retina is negatively charged, and the cornea is positively charged.
69
If we think about something as simple as an eye blink, in this crude diagram, when the patient blinks their eye,
70
the eyeball moves upward into the head, a phenomenon known as a Bell's phenomenon.
71
This is the normal response during eye blinking.
72
If we think about this from the perspective of the EEG electrodes closest to the eye, we can see
73
that this upward deflection of the eye will cause a large positive signal at the frontal polar electrodes FP1 and FP2.
74
On EEG, this results in a very large deflection in the frontal polar electrodes on both sides, indicated here.
75
The alpha rhythm is the most commonly encountered rhythm during wakefulness.
76
Here, I have highlighted the alpha rhythm.
77
The alpha rhythm is a normal rhythm during wakefulness and is especially prominent when the eyes are closed.
78
Although there is a range of frequencies for the alpha rhythm, it is usually around 10 hertz or so, which is the case in this patient.
79
Focal epileptiform discharges are generated by synchronous abnormal electrical activity in a large population of neurons in the cortex.
80
Focal epileptiform discharges can be an indicator
81
that the brain is capable of generating seizures and can be a helpful prognostic and diagnostic finding in patients with epilepsy.
82
Here, I have a normal awake EEG and an anterior -posterior bipolar montage.
83
Without going into too many details, there is a focal epileptiform discharge here.
84
You can see that this is in the left temporal chain.
85
I will go into how to sort out the polarity of this epileptiform discharge in a separate video,
86
but here I've indicated the areas of maximum abnormality for this particular epileptiform discharge.
87
Here is a slightly different focal epileptiform discharge.
88
Whereas the other discharge was maximal in the temporal region, this discharge is maximal in the posterior aspect of the head,
89
on the right side, and I have shown its maximal field in this diagram.
90
Generalized epileptiform discharges are seen in patients with generalized epilepsy syndromes.
91
Here is an example of a run of generalized epileptiform discharges.
92
You can see that these discharges involve basically the whole head all at once.
93
There is a long run of these discharges, lasting almost the entire length of this page.
94
These are actually the typical 3 Hz generalized spike -and -wave discharges seen in childhood absence epilepsy.
95
It is useful to think about the diagnostic yield of EEG.
96
In studies of patients with epilepsy, the likelihood of finding an epileptiform discharge,
97
either focal or generalized, in a single EEG within 24 hours of a first seizure is about 50%.
98
If the EEG is done more than 24 hours after the first seizure, the likelihood might drop somewhat.
99
This means that half or even more than half of patients with epilepsy might have a normal routine EEG.
100
On prolonged 24 -hour EEG recording, the likelihood of picking up some epileptiform discharges is much higher, in the range of 80 -90%.
101
But again, this means that 10 -20 % of the time, even prolonged EEG can be normal in a patient with epilepsy.
102
Several routine 30 -60 minute EEG recordings can produce the same yield as a 24 -hour recording, but may be less practical.
103
To think about why some patients with epilepsy might not have epileptiform discharges, we can consider a couple of things.
104
Here I have shown a coronal section of a brain.
105
I have placed the approximate position of the standard EEG electrodes on this image.
106
The two major determinants of seeing a scalp abnormality are the area of cortex involved and the location.
107
For example, I have shown here a star which represents a small area of cortex that has synchronous abnormal electrical activity.
108
Because this area is small, it might not be picked up by the overlying electrodes.
109
If a larger area is involved,
110
such as shown here, it might be more likely that this abnormality would be picked up by scalp electrodes. In general,
111
10 to 20 square centimeters of cortex has to be involved
112
in order for the abnormality to be consistently demonstrated on scalp EEG.
113
The other main determinant of a scalp abnormality on EEG is the location of the synchronous cortical activity.
114
In this example, I have shown a very superficial area of cortex involved, which might be more likely to be picked up by scalp EEG electrodes.
115
If a deeper area of cortex was involved, such as in the cingulate gyrus, shown here, in the mesial temporal structure,
116
shown here, or in the insular cortex,
117
shown here, it may be less likely that such abnormalities would be picked up by the more distant scalp electrodes.
118
In this video, we have reviewed basic EEG terminology, how EEG data is recorded and displayed,
119
some common EEG patterns, and how EEG may be used in clinical neurology.
120
Obviously, this is a very superficial review of EEG,
121
and for further details, feel free to peruse some of the other videos which explore EEG in further depth.

下载应用

流利口语所需的一切

AI 发音评分逐句打分
音标练习掌握每个音
词汇学习建立你的词库
词汇游戏边玩边学
FOR YOU

推荐视频

本课的词汇与口语要点

这节口语课以视频“Introduction to EEG”为素材。 视频中反复出现的词有:Eeg, electrode, discharge, epileptiform, montage。 这段视频共有 121 个句子、1851 个单词可供跟读。 讲话部分时长为 11:30。 说话人语速自然,每分钟约 161 个词,接近日常对话。 只有 75% 的单词属于英语最常用的 3,000 词,词汇难度较高。

视频中的重点词汇

视频中 15 个值得学习的单词,附发音和释义:

单词发音释义
cortex 名词/ˈkɔɹtɛks/皮质
rhythm 名词/ˈɹɪð.əm/節奏 /节奏
temporal 形容词/ˈtɛm.pə.ɹəl/世俗的
input 名词/ˈɪnpʊt/輸入 /输入
measurement 名词/ˈmɛʒ.ə.mənt/尺寸
indicate 动词/ˈɪndɪˌkeɪt/表明, 表示
alpha 名词/ˈæl.fə/阿爾法 /阿尔法, 阿伐
blink 动词/ˈblɪŋk/眨眼, 眨眼睛
anterior 形容词/ænˈtɪɹ.i.ɚ/前部
output 名词/ˈaʊtpʊt/輸出 /输出
commonly 副词/ˈkɑmənli/通常
encounter 动词/ɪnˈkaʊntɚ/遇到, 遇見 /遇见
likelihood 名词/ˈlaɪklihʊd/可能性
diagram 名词/ˈdaɪ.ə.ɡɹæm/圖 /图, 圖表 /图表
seizure 名词/ˈsi.ʒɚ/奪取 /夺取, 佔用 /占用

视频中出现的短语动词

单词释义
pick up 动词拾取, 撿 /捡

视频中的语法

说话人最常用的结构,并附上视频中的原话:

结构视频中的用法
被动语态 be + 过去分词 — 强调发生了什么,而不是谁做的can be used · will be reviewed · is recorded
现在完成时 have/has + 过去分词 — 过去发生但与现在仍有关联的事have been placed · have highlighted · I've indicated
定语从句 who / which + 从句 — 补充说明人或事物waveforms, which are · ways which are

需要注意的发音

  • “sh” 和 “zh” 音: measurement /ˈmɛʒ.ə.mənt/, differential [dɪfəˈɹənʃəɫ], seizure /ˈsi.ʒɚ/, superficial /ˌsupɚˈfɪʃəl/, interpretation /ɪnˌtɜːpɹəˈteɪʃən/
  • 长单词——注意重音位置: electrical /ɪˈlɛktɹɪkəl/, differential [dɪfəˈɹənʃəɫ], anterior /ænˈtɪɹ.i.ɚ/, terminology /ˌtɝ.məˈnɑ.lə.d͡ʒi/, phenomenon /fəˈnɒm.ɪ.nən/

中文母语者容易读错的音:

  • /v/ — 不要读成 /w/,上齿轻触下唇: divide /dɪˈvaɪd/, relative /ˈɹɛl.ə.tɪv/, involve /ɪnˈvɑlv/, dive /daɪv/, positively /ˈpɑ.zɪ.tɪv.li/
  • 词尾辅音 — 要读清楚,后面不要加元音: discharge /dɪsˈtʃɑɹdʒ/, cortex /ˈkɔɹtɛks/, input /ˈɪnpʊt/, measurement /ˈmɛʒ.ə.mənt/, indicate /ˈɪndɪˌkeɪt/
  • /r/ 和 /l/ 的区别: temporal /ˈtɛm.pə.ɹəl/, electrical /ɪˈlɛktɹɪkəl/, differential [dɪfəˈɹənʃəɫ], briefly /ˈbɹiːfli/, abnormal /ˌæbˈnɔɹ.ml̩/

如何用这段视频练习

  1. 先完整听一遍视频,不要开口,记下不认识的单词。
  2. 先用 0.75 倍速逐句跟读,熟练之后再回到正常速度。
  3. 录下自己的声音并与原声对比,特别注意 cortex, rhythm, temporal 这类单词。

什么是跟读法?

跟读法 (Shadowing) 是一种有科学依据的语言学习技巧,最初开发用于专业口译员的培训,并由多语言者Alexander Arguelles博士普及。这个方法简单而强大:您在听英语母语原声的同时立即大声重复——就像是一个延迟1-2秒紧跟说话者的影子。与被动听力或语法练习不同,跟读法强迫您的大脑和口腔肌肉同时处理并模仿真实的讲话模式。研究表明它能显着提高发音准确性,语调,节奏,连读,听力理解和口语流利度——使其成为雅思口语备考和真实英语交流最有效的方法之一。

影子跟读法: 阅读完整分步指南 →