跟讀練習: Introduction to EEG - 通過影片學習英語口語
選擇練習模式
每種模式都會開啟全屏練習室。
121 句
如果句子過短或過長,請點選 Edit 進行調整。
1
In this video, we will review the basics of the electroencephalogram, or EEG, how it's recorded, and how the results can be used in clinical neurology.
2
We will review several topics briefly during this video.
3
The topics will be reviewed in further detail in subsequent videos for those interested in deeper dives into the world of EEG.
4
We will review some of the basic terminology of EEG, how EEG is recorded, how EEG is displayed for interpretation,
5
some common EEG patterns, and how we can use the results of EEG for making decisions in clinical neurology.
6
First, we will start with the terminology.
7
The system by which EEG electrodes are applied to the head
8
and then displayed on EEG recordings is called the International 1020 system.
9
The International 1020 system is a standard method of measuring the head and placing electrodes.
10
It depends on four main positions on the head that are easily transferable between patients.
11
First is the nasion at the bridge of the nose, then the inion, the bony prominence at the back of the head,
12
and then two preauricular points just anterior to each ear.
13
Consider this diagram of a head looking from the top down.
14
The first measurement that is made is from the nasion to the inion, front to back.
15
This measurement is then divided into 10 and 20 % increments, and this is how the 10 -20 system gets its name.
16
Marks are placed, and then a measurement is made from one preauricular point to the other.
17
Again, this is divided into 10 and 20 % increments, and additional marks are made.
18
Further marks are made around the circumference of the head, and separated by 10 % increments.
19
And then parasagittal measurements are made, separated by 25 % increments.
20
And finally, transverse measurements are made.
21
The intersections of these two lines is where the final electrodes are placed.
22
Once all of these marks have been placed, the electrodes can be applied to the scalp of the patient.
23
The electrodes are labeled, as is shown here.
24
The system is very simple, and each electrode is represented by letters and a number.
25
The numbers indicate the side of the head, so that odd numbers are on the left side, and even numbers are on the right.
26
In general, lower numbers mean that the electrode is closer to the midline,
27
so you can see here that C4 is closer to the midline than T8,
28
and the midline itself is represented by a Z, which stands for zero.
29
The letters are indicators of the position on the head.
30
In this central chain of electrodes, you can see that the F stands for frontal, the C for central, and the P for parietal.
31
EEG is recorded using the technology of the differential amplifier.
32
The differential amplifier takes two electrical inputs and displays the output as the difference between the two inputs.
33
This is particularly useful at recording and displaying very small electrical signals, such as those in EEG.
34
For example, you can see these two waveforms, which are very similar, except for one small difference demonstrated here in red.
35
When these two signals are placed through a differential amplifier, you can see that the output is simply the difference between them,
36
and all of the other commonalities are cancelled out.
37
Another way to think about this is to think about the very common children's game that is seen on restaurant menus.
38
You can see that the picture on the left and the picture on the right are very similar, except for a few small differences indicated here.
39
If we were to consider the picture on the left as input one and the picture on the right as input two,
40
we could put these two quote -unquote signals through a differential amplifier and the output would look like this.
41
This example is a good way of thinking about EEG signals as something
42
that is not absolute but rather the difference between two inputs.
43
EEG can be displayed in different ways which are all known as montages.
44
The most common type of montage is a bipolar montage.
45
Here, I have a picture of the head from the top down.
46
If we display the difference between fp2 and f8 as a single tracing, it would look something like this,
47
and we call this single tracing a channel or derivation.
48
Next, we move posteriorly and look at the difference between f8 and t8 and display this as a different channel.
49
We continue to move posteriorly, and we have a string of recordings from the front of the head to the back that are linked together.
50
This string of recordings is called a chain.
51
In this case, this is the right temporal chain.
52
Several chains can be placed together in a single display, such as this example of an anterior -posterior bipolar montage.
53
This anterior -posterior bipolar montage is laid out as
54
if we are looking at the top of the head of the patient and they are facing to the right.
55
Therefore, we first see the left temporal chain, then the left parasagittal chain, then the midline, then the right parasagittal chain,
56
and then the right temporal chain.
57
At the bottom, we see a single EKG channel as well.
58
Another common type of montage is called a common average reference montage.
59
Here, in a single channel, rather than looking at the difference between two adjacent electrodes, as in a bipolar montage,
60
we look at the difference between an electrode of interest and an average of the signals of the rest of the head.
61
Here we can see the layout of an average reference montage,
62
which is very similar, but again we are comparing each channel to an average of the rest of the head.
63
Some relative strengths and weaknesses of different montages are reviewed in a separate video.
64
I will briefly review some commonly encountered EEG patterns, simply to whet your appetite for further EEG learning.
65
One of the most commonly encountered entities on an EEG recording is an eye blink, and so I will review this briefly.
66
We have to think about the eye as a dipole with a polarity.
67
There is the retina and the cornea.
68
The retina is negatively charged, and the cornea is positively charged.
69
If we think about something as simple as an eye blink, in this crude diagram, when the patient blinks their eye,
70
the eyeball moves upward into the head, a phenomenon known as a Bell's phenomenon.
71
This is the normal response during eye blinking.
72
If we think about this from the perspective of the EEG electrodes closest to the eye, we can see
73
that this upward deflection of the eye will cause a large positive signal at the frontal polar electrodes FP1 and FP2.
74
On EEG, this results in a very large deflection in the frontal polar electrodes on both sides, indicated here.
75
The alpha rhythm is the most commonly encountered rhythm during wakefulness.
76
Here, I have highlighted the alpha rhythm.
77
The alpha rhythm is a normal rhythm during wakefulness and is especially prominent when the eyes are closed.
78
Although there is a range of frequencies for the alpha rhythm, it is usually around 10 hertz or so, which is the case in this patient.
79
Focal epileptiform discharges are generated by synchronous abnormal electrical activity in a large population of neurons in the cortex.
80
Focal epileptiform discharges can be an indicator
81
that the brain is capable of generating seizures and can be a helpful prognostic and diagnostic finding in patients with epilepsy.
82
Here, I have a normal awake EEG and an anterior -posterior bipolar montage.
83
Without going into too many details, there is a focal epileptiform discharge here.
84
You can see that this is in the left temporal chain.
85
I will go into how to sort out the polarity of this epileptiform discharge in a separate video,
86
but here I've indicated the areas of maximum abnormality for this particular epileptiform discharge.
87
Here is a slightly different focal epileptiform discharge.
88
Whereas the other discharge was maximal in the temporal region, this discharge is maximal in the posterior aspect of the head,
89
on the right side, and I have shown its maximal field in this diagram.
90
Generalized epileptiform discharges are seen in patients with generalized epilepsy syndromes.
91
Here is an example of a run of generalized epileptiform discharges.
92
You can see that these discharges involve basically the whole head all at once.
93
There is a long run of these discharges, lasting almost the entire length of this page.
94
These are actually the typical 3 Hz generalized spike -and -wave discharges seen in childhood absence epilepsy.
95
It is useful to think about the diagnostic yield of EEG.
96
In studies of patients with epilepsy, the likelihood of finding an epileptiform discharge,
97
either focal or generalized, in a single EEG within 24 hours of a first seizure is about 50%.
98
If the EEG is done more than 24 hours after the first seizure, the likelihood might drop somewhat.
99
This means that half or even more than half of patients with epilepsy might have a normal routine EEG.
100
On prolonged 24 -hour EEG recording, the likelihood of picking up some epileptiform discharges is much higher, in the range of 80 -90%.
101
But again, this means that 10 -20 % of the time, even prolonged EEG can be normal in a patient with epilepsy.
102
Several routine 30 -60 minute EEG recordings can produce the same yield as a 24 -hour recording, but may be less practical.
103
To think about why some patients with epilepsy might not have epileptiform discharges, we can consider a couple of things.
104
Here I have shown a coronal section of a brain.
105
I have placed the approximate position of the standard EEG electrodes on this image.
106
The two major determinants of seeing a scalp abnormality are the area of cortex involved and the location.
107
For example, I have shown here a star which represents a small area of cortex that has synchronous abnormal electrical activity.
108
Because this area is small, it might not be picked up by the overlying electrodes.
109
If a larger area is involved,
110
such as shown here, it might be more likely that this abnormality would be picked up by scalp electrodes. In general,
111
10 to 20 square centimeters of cortex has to be involved
112
in order for the abnormality to be consistently demonstrated on scalp EEG.
113
The other main determinant of a scalp abnormality on EEG is the location of the synchronous cortical activity.
114
In this example, I have shown a very superficial area of cortex involved, which might be more likely to be picked up by scalp EEG electrodes.
115
If a deeper area of cortex was involved, such as in the cingulate gyrus, shown here, in the mesial temporal structure,
116
shown here, or in the insular cortex,
117
shown here, it may be less likely that such abnormalities would be picked up by the more distant scalp electrodes.
118
In this video, we have reviewed basic EEG terminology, how EEG data is recorded and displayed,
119
some common EEG patterns, and how EEG may be used in clinical neurology.
120
Obviously, this is a very superficial review of EEG,
121
and for further details, feel free to peruse some of the other videos which explore EEG in further depth.
FOR YOU
推薦影片
本課的詞彙與口語要點
這節口語課以影片“Introduction to EEG”為素材。 影片中反覆出現的詞有:Eeg, electrode, discharge, epileptiform, montage。 這段影片共有 121 個句子、1851 個單詞可供跟讀。 講話部分時長為 11:30。 說話人語速自然,每分鐘約 161 個詞,接近日常對話。 只有 75% 的單詞屬於英語最常用的 3,000 詞,詞彙難度較高。
影片中的重點詞彙
影片中 15 個值得學習的單詞,附發音和釋義:
| 單詞 | 發音 | 釋義 |
|---|---|---|
| cortex 名詞 | /ˈkɔɹtɛks/ | 皮質 |
| rhythm 名詞 | /ˈɹɪð.əm/ | 節奏 /節奏 |
| temporal 形容詞 | /ˈtɛm.pə.ɹəl/ | 世俗的 |
| input 名詞 | /ˈɪnpʊt/ | 輸入 /輸入 |
| measurement 名詞 | /ˈmɛʒ.ə.mənt/ | 尺寸 |
| indicate 動詞 | /ˈɪndɪˌkeɪt/ | 表明, 表示 |
| alpha 名詞 | /ˈæl.fə/ | 阿爾法 /阿爾法, 阿伐 |
| blink 動詞 | /ˈblɪŋk/ | 眨眼, 眨眼睛 |
| anterior 形容詞 | /ænˈtɪɹ.i.ɚ/ | 前部 |
| output 名詞 | /ˈaʊtpʊt/ | 輸出 /輸出 |
| commonly 副詞 | /ˈkɑmənli/ | 通常 |
| encounter 動詞 | /ɪnˈkaʊntɚ/ | 遇到, 遇見 /遇見 |
| likelihood 名詞 | /ˈlaɪklihʊd/ | 可能性 |
| diagram 名詞 | /ˈdaɪ.ə.ɡɹæm/ | 圖 /圖, 圖表 /圖表 |
| seizure 名詞 | /ˈsi.ʒɚ/ | 奪取 /奪取, 佔用 /佔用 |
影片中出現的短語動詞
| 單詞 | 釋義 |
|---|---|
| pick up 動詞 | 拾取, 撿 /撿 |
影片中的語法
說話人最常用的結構,並附上影片中的原話:
| 結構 | 影片中的用法 |
|---|---|
| 被動語態 be + 過去分詞 — 強調發生了什麼,而不是誰做的 | can be used · will be reviewed · is recorded |
| 現在完成時 have/has + 過去分詞 — 過去發生但與現在仍有關聯的事 | have been placed · have highlighted · I've indicated |
| 定語從句 who / which + 從句 — 補充說明人或事物 | waveforms, which are · ways which are |
需要注意的發音
- “sh” 和 “zh” 音: measurement /ˈmɛʒ.ə.mənt/, differential [dɪfəˈɹənʃəɫ], seizure /ˈsi.ʒɚ/, superficial /ˌsupɚˈfɪʃəl/, interpretation /ɪnˌtɜːpɹəˈteɪʃən/
- 長單詞——注意重音位置: electrical /ɪˈlɛktɹɪkəl/, differential [dɪfəˈɹənʃəɫ], anterior /ænˈtɪɹ.i.ɚ/, terminology /ˌtɝ.məˈnɑ.lə.d͡ʒi/, phenomenon /fəˈnɒm.ɪ.nən/
中文母語者容易讀錯的音:
- /v/ — 不要讀成 /w/,上齒輕觸下唇: divide /dɪˈvaɪd/, relative /ˈɹɛl.ə.tɪv/, involve /ɪnˈvɑlv/, dive /daɪv/, positively /ˈpɑ.zɪ.tɪv.li/
- 詞尾子音 — 要讀清楚,後面不要加母音: discharge /dɪsˈtʃɑɹdʒ/, cortex /ˈkɔɹtɛks/, input /ˈɪnpʊt/, measurement /ˈmɛʒ.ə.mənt/, indicate /ˈɪndɪˌkeɪt/
- /r/ 和 /l/ 的區別: temporal /ˈtɛm.pə.ɹəl/, electrical /ɪˈlɛktɹɪkəl/, differential [dɪfəˈɹənʃəɫ], briefly /ˈbɹiːfli/, abnormal /ˌæbˈnɔɹ.ml̩/
如何用這段影片練習
- 先完整聽一遍影片,不要開口,記下不認識的單詞。
- 先用 0.75 倍速逐句跟讀,熟練之後再回到正常速度。
- 錄下自己的聲音並與原聲對比,特別注意 cortex, rhythm, temporal 這類單詞。
什麼是跟讀法?
跟讀法 (Shadowing) 是一種有科學依據的語言學習技巧,最初開發用於專業口譯員的培訓,並由多語言者Alexander Arguelles博士普及。這個方法簡單而強大:您在聽英語母語原聲的同時立即大聲重複——就像是一個延遲1-2秒緊跟說話者的影子。與被動聽力或語法練習不同,跟讀法強迫您的大腦和口腔肌肉同時處理並模模擬實的講話模式。研究表明它能顯著提高發音準確性,語調,節奏,連讀,聽力理解和口語流利度——使其成為雅思口語備考和真實英語交流最有效的方法之一。












![[Lecture Ready3] Ch10 Lecture2](https://img.youtube.com/vi/8FVVfebHarQ/mqdefault.jpg)