1
In this video, we will review the basics of the electroencephalogram, or EEG, how it's recorded, and how the results can be used in clinical neurology.
2
We will review several topics briefly during this video.
3
The topics will be reviewed in further detail in subsequent videos for those interested in deeper dives into the world of EEG.
4
We will review some of the basic terminology of EEG, how EEG is recorded, how EEG is displayed for interpretation,
5
some common EEG patterns, and how we can use the results of EEG for making decisions in clinical neurology.
6
First, we will start with the terminology.
7
The system by which EEG electrodes are applied to the head
8
and then displayed on EEG recordings is called the International 1020 system.
9
The International 1020 system is a standard method of measuring the head and placing electrodes.
10
It depends on four main positions on the head that are easily transferable between patients.
11
First is the nasion at the bridge of the nose, then the inion, the bony prominence at the back of the head,
12
and then two preauricular points just anterior to each ear.
13
Consider this diagram of a head looking from the top down.
14
The first measurement that is made is from the nasion to the inion, front to back.
15
This measurement is then divided into 10 and 20 % increments, and this is how the 10 -20 system gets its name.
16
Marks are placed, and then a measurement is made from one preauricular point to the other.
17
Again, this is divided into 10 and 20 % increments, and additional marks are made.
18
Further marks are made around the circumference of the head, and separated by 10 % increments.
19
And then parasagittal measurements are made, separated by 25 % increments.
20
And finally, transverse measurements are made.
21
The intersections of these two lines is where the final electrodes are placed.
22
Once all of these marks have been placed, the electrodes can be applied to the scalp of the patient.
23
The electrodes are labeled, as is shown here.
24
The system is very simple, and each electrode is represented by letters and a number.
25
The numbers indicate the side of the head, so that odd numbers are on the left side, and even numbers are on the right.
26
In general, lower numbers mean that the electrode is closer to the midline,
27
so you can see here that C4 is closer to the midline than T8,
28
and the midline itself is represented by a Z, which stands for zero.
29
The letters are indicators of the position on the head.
30
In this central chain of electrodes, you can see that the F stands for frontal, the C for central, and the P for parietal.
31
EEG is recorded using the technology of the differential amplifier.
32
The differential amplifier takes two electrical inputs and displays the output as the difference between the two inputs.
33
This is particularly useful at recording and displaying very small electrical signals, such as those in EEG.
34
For example, you can see these two waveforms, which are very similar, except for one small difference demonstrated here in red.
35
When these two signals are placed through a differential amplifier, you can see that the output is simply the difference between them,
36
and all of the other commonalities are cancelled out.
37
Another way to think about this is to think about the very common children's game that is seen on restaurant menus.
38
You can see that the picture on the left and the picture on the right are very similar, except for a few small differences indicated here.
39
If we were to consider the picture on the left as input one and the picture on the right as input two,
40
we could put these two quote -unquote signals through a differential amplifier and the output would look like this.
41
This example is a good way of thinking about EEG signals as something
42
that is not absolute but rather the difference between two inputs.
43
EEG can be displayed in different ways which are all known as montages.
44
The most common type of montage is a bipolar montage.
45
Here, I have a picture of the head from the top down.
46
If we display the difference between fp2 and f8 as a single tracing, it would look something like this,
47
and we call this single tracing a channel or derivation.
48
Next, we move posteriorly and look at the difference between f8 and t8 and display this as a different channel.
49
We continue to move posteriorly, and we have a string of recordings from the front of the head to the back that are linked together.
50
This string of recordings is called a chain.
51
In this case, this is the right temporal chain.
52
Several chains can be placed together in a single display, such as this example of an anterior -posterior bipolar montage.
53
This anterior -posterior bipolar montage is laid out as
54
if we are looking at the top of the head of the patient and they are facing to the right.
55
Therefore, we first see the left temporal chain, then the left parasagittal chain, then the midline, then the right parasagittal chain,
56
and then the right temporal chain.
57
At the bottom, we see a single EKG channel as well.
58
Another common type of montage is called a common average reference montage.
59
Here, in a single channel, rather than looking at the difference between two adjacent electrodes, as in a bipolar montage,
60
we look at the difference between an electrode of interest and an average of the signals of the rest of the head.
61
Here we can see the layout of an average reference montage,
62
which is very similar, but again we are comparing each channel to an average of the rest of the head.
63
Some relative strengths and weaknesses of different montages are reviewed in a separate video.
64
I will briefly review some commonly encountered EEG patterns, simply to whet your appetite for further EEG learning.
65
One of the most commonly encountered entities on an EEG recording is an eye blink, and so I will review this briefly.
66
We have to think about the eye as a dipole with a polarity.
67
There is the retina and the cornea.
68
The retina is negatively charged, and the cornea is positively charged.
69
If we think about something as simple as an eye blink, in this crude diagram, when the patient blinks their eye,
70
the eyeball moves upward into the head, a phenomenon known as a Bell's phenomenon.
71
This is the normal response during eye blinking.
72
If we think about this from the perspective of the EEG electrodes closest to the eye, we can see
73
that this upward deflection of the eye will cause a large positive signal at the frontal polar electrodes FP1 and FP2.
74
On EEG, this results in a very large deflection in the frontal polar electrodes on both sides, indicated here.
75
The alpha rhythm is the most commonly encountered rhythm during wakefulness.
76
Here, I have highlighted the alpha rhythm.
77
The alpha rhythm is a normal rhythm during wakefulness and is especially prominent when the eyes are closed.
78
Although there is a range of frequencies for the alpha rhythm, it is usually around 10 hertz or so, which is the case in this patient.
79
Focal epileptiform discharges are generated by synchronous abnormal electrical activity in a large population of neurons in the cortex.
80
Focal epileptiform discharges can be an indicator
81
that the brain is capable of generating seizures and can be a helpful prognostic and diagnostic finding in patients with epilepsy.
82
Here, I have a normal awake EEG and an anterior -posterior bipolar montage.
83
Without going into too many details, there is a focal epileptiform discharge here.
84
You can see that this is in the left temporal chain.
85
I will go into how to sort out the polarity of this epileptiform discharge in a separate video,
86
but here I've indicated the areas of maximum abnormality for this particular epileptiform discharge.
87
Here is a slightly different focal epileptiform discharge.
88
Whereas the other discharge was maximal in the temporal region, this discharge is maximal in the posterior aspect of the head,
89
on the right side, and I have shown its maximal field in this diagram.
90
Generalized epileptiform discharges are seen in patients with generalized epilepsy syndromes.
91
Here is an example of a run of generalized epileptiform discharges.
92
You can see that these discharges involve basically the whole head all at once.
93
There is a long run of these discharges, lasting almost the entire length of this page.
94
These are actually the typical 3 Hz generalized spike -and -wave discharges seen in childhood absence epilepsy.
95
It is useful to think about the diagnostic yield of EEG.
96
In studies of patients with epilepsy, the likelihood of finding an epileptiform discharge,
97
either focal or generalized, in a single EEG within 24 hours of a first seizure is about 50%.
98
If the EEG is done more than 24 hours after the first seizure, the likelihood might drop somewhat.
99
This means that half or even more than half of patients with epilepsy might have a normal routine EEG.
100
On prolonged 24 -hour EEG recording, the likelihood of picking up some epileptiform discharges is much higher, in the range of 80 -90%.
101
But again, this means that 10 -20 % of the time, even prolonged EEG can be normal in a patient with epilepsy.
102
Several routine 30 -60 minute EEG recordings can produce the same yield as a 24 -hour recording, but may be less practical.
103
To think about why some patients with epilepsy might not have epileptiform discharges, we can consider a couple of things.
104
Here I have shown a coronal section of a brain.
105
I have placed the approximate position of the standard EEG electrodes on this image.
106
The two major determinants of seeing a scalp abnormality are the area of cortex involved and the location.
107
For example, I have shown here a star which represents a small area of cortex that has synchronous abnormal electrical activity.
108
Because this area is small, it might not be picked up by the overlying electrodes.
109
If a larger area is involved,
110
such as shown here, it might be more likely that this abnormality would be picked up by scalp electrodes. In general,
111
10 to 20 square centimeters of cortex has to be involved
112
in order for the abnormality to be consistently demonstrated on scalp EEG.
113
The other main determinant of a scalp abnormality on EEG is the location of the synchronous cortical activity.
114
In this example, I have shown a very superficial area of cortex involved, which might be more likely to be picked up by scalp EEG electrodes.
115
If a deeper area of cortex was involved, such as in the cingulate gyrus, shown here, in the mesial temporal structure,
116
shown here, or in the insular cortex,
117
shown here, it may be less likely that such abnormalities would be picked up by the more distant scalp electrodes.
118
In this video, we have reviewed basic EEG terminology, how EEG data is recorded and displayed,
119
some common EEG patterns, and how EEG may be used in clinical neurology.
120
Obviously, this is a very superficial review of EEG,
121
and for further details, feel free to peruse some of the other videos which explore EEG in further depth.

앱 다운로드

유창하게 말하는 데 필요한 모든 것

AI 발음 평가문장마다 점수 확인
IPA 발음 연습모든 소리 마스터
단어 학습나만의 단어장 만들기
단어 게임놀면서 외우기
FOR YOU

추천 영상

이 레슨의 어휘와 말하기 포인트

이 말하기 레슨은 영상 “Introduction to EEG”을(를) 바탕으로 합니다. 가장 자주 반복되는 단어는 다음과 같습니다: Eeg, electrode, discharge, epileptiform, montage. 이 영상에는 섀도잉할 문장 121개와 단어 1851개가 있습니다. 말하는 구간의 길이는 11:30입니다. 화자는 분당 약 161단어로, 일상 대화에 가까운 자연스러운 속도로 말합니다. 영어에서 가장 많이 쓰이는 3,000단어에 속하는 단어가 75%뿐이라 어휘가 어려운 편입니다.

이 영상의 핵심 어휘

영상에 나오는 익혀 둘 만한 단어 15개를 발음, 뜻과 함께 정리했습니다.

단어발음뜻
cortex 명사/ˈkɔɹtɛks/피질
rhythm 명사/ˈɹɪð.əm/리듬
measurement 명사/ˈmɛʒ.ə.mənt/측정
indicate 동사/ˈɪndɪˌkeɪt/가리키다
alpha 명사/ˈæl.fə/알파
blink 동사/ˈblɪŋk/눈을 깜박이다, 눈을 깜박거리다
output 명사/ˈaʊtpʊt/출력
encounter 동사/ɪnˈkaʊntɚ/만나다, 부닥치다
likelihood 명사/ˈlaɪklihʊd/가능성
diagram 명사/ˈdaɪ.ə.ɡɹæm/다이어그램, 도표
terminology 명사/ˌtɝ.məˈnɑ.lə.d͡ʒi/술어학
topic 명사/ˈtɑpɪk/화제, 주제
string 명사/stɹɪŋ/끈
routine 명사/ɹuˈtin/일과, 루틴
trace 명사/tɹeɪs/흔적, 자국

영상에 나오는 구동사

단어뜻
pick up 동사줍다

이 영상의 문법

화자가 가장 많이 쓰는 문형을 영상 속 실제 표현과 함께 정리했습니다.

문형영상 속 표현
수동태 be + 과거분사 — 누가 하는지보다 무슨 일이 일어나는지에 초점can be used · will be reviewed · is recorded
현재완료 have/has + 과거분사 — 과거의 일이 지금도 관련이 있을 때have been placed · have highlighted · I've indicated
관계절 who / which + 절 — 사람이나 사물에 대한 추가 정보waveforms, which are · ways which are

주의할 발음

  • “sh”와 “zh” 소리: measurement /ˈmɛʒ.ə.mənt/, differential [dɪfəˈɹənʃəɫ], seizure /ˈsi.ʒɚ/, superficial /ˌsupɚˈfɪʃəl/, interpretation /ɪnˌtɜːpɹəˈteɪʃən/
  • 긴 단어 — 강세 위치에 주의: electrical /ɪˈlɛktɹɪkəl/, differential [dɪfəˈɹənʃəɫ], anterior /ænˈtɪɹ.i.ɚ/, terminology /ˌtɝ.məˈnɑ.lə.d͡ʒi/, phenomenon /fəˈnɒm.ɪ.nən/

한국어 화자가 어려워하는 소리:

  • /f/ — ㅍ(/p/)으로 바꾸지 말고 윗니를 아랫입술에 대기: focal /ˈfoʊ.kl̩/, alpha /ˈæl.fə/, differential [dɪfəˈɹənʃəɫ], briefly /ˈbɹiːfli/, phenomenon /fəˈnɒm.ɪ.nən/
  • /v/ — ㅂ(/b/)과 구별하기: divide /dɪˈvaɪd/, relative /ˈɹɛl.ə.tɪv/, involve /ɪnˈvɑlv/, dive /daɪv/, positively /ˈpɑ.zɪ.tɪv.li/
  • /z/ — ㅈ이 아니라 성대를 울리는 /s/: whereas /(h)wɛɹˈæz/, positively /ˈpɑ.zɪ.tɪv.li/, generalize /ˈd͡ʒɛn.(ə.)ɹə.laɪz/, mesial /ˈmiːzɪəl/, peruse /pəˈɹuːz/

이 영상으로 연습하는 방법

  1. 먼저 말하지 않고 영상을 끝까지 듣고 모르는 단어를 적어 둡니다.
  2. 0.75배속으로 한 문장씩 섀도잉을 시작하고, 익숙해지면 보통 속도로 돌아갑니다.
  3. 자신의 목소리를 녹음해 원본과 비교하고, cortex, rhythm, measurement 같은 단어에 특히 주의합니다.

쉐도잉이란? 영어 실력을 빠르게 키우는 과학적 방법

쉐도잉(Shadowing)은 원래 전문 통역사 훈련을 위해 개발된 언어 학습 기법으로, 다언어 학자인 Dr. Alexander Arguelles에 의해 대중화된 방법입니다. 핵심 원리는 간단하지만 매우 강력합니다: 원어민의 영어를 들으면서 1~2초의 짧은 지연으로 즉시 소리 내어 따라 말하는 것——마치 '그림자(shadow)'처럼 화자를 따라가는 것입니다. 문법 공부나 수동적인 청취와 달리, 쉐도잉은 뇌와 입 근육이 동시에 실시간으로 영어를 처리하고 재현하도록 훈련합니다. 연구에 따르면 이 방법은 발음 정확도, 억양, 리듬, 연음, 청취력, 말하기 유창성을 크게 향상시킵니다. IELTS 스피킹 준비와 자연스러운 영어 소통을 원하는 분들에게 특히 효과적입니다.

섀도잉 방법: 단계별 전체 가이드 읽기 →