In this video, we're going to talk about syncing and sourcing PLC digital input modules and how they're connected to field devices.
2
We will be using a Siemens digital input module with this part number.
3
If you want to order this module online, you can head on over to the RealPars Marketplace or simply click on this link here.
4
The two types of PLC input modules are digital and analog.
5
A digital input module accepts inputs from digital devices such as switches and proximity sensors.
6
The input module will detect one of the two possible conditions of an input device, open or closed.
7
For example, a push -button switch is a digital device and can either be open or closed.
8
We will examine how the input module detects the input device condition later in this video.
9
The focus of our video is on digital input modules.
10
Okay, let's go.
11
As we said earlier, a digital input module will detect one of the two possible conditions of an input device, open or closed.
12
So, the question is, how does the input module know if the input device is open or closed?
13
All we need to do is construct a closed circuit containing the input device,
14
the PLC input module, and a 24 volt DC power supply.
15
If the switch is open, there is 0 volts at the module input terminal.
16
If the switch is closed, there is a positive 24 volts at the module input terminal.
17
The input module will detect either a no voltage or voltage condition at the input.
18
These voltage conditions represent the open or closed conditions of the switch.
19
These voltage or non -voltage conditions are represented by ones and zeros in the PLC memory.
20
Every input device is connected the same way.
21
If you have a 64 input module, it's possible to have 64 separate circuits.
22
We'll show you more examples later.
23
Alright, now that we know how the digital input module determines the input device condition,
24
let's talk about the current flow between the power supply and the input module.
25
There is a current flow, but it is very small and usually under 10 milliamps.
26
Notice in our example that the current is flowing into the PLC module.
27
Depending on the type of PLC input module and how it's connected with the input device, the current could flow in or out of the module.
28
That's where the terms sinking and sourcing come into the picture.
29
Let's spend some time clearing up any misconceptions you might have about these terms.
30
When we talk about sinking and sourcing, it's all about defining the direction of conventional current flow between two devices.
31
Think of it this way, current is flowing between device number 1 and device number 2.
32
Ask yourself, which direction is the current flowing?
33
The current is flowing from device number 1 to device number 2.
34
Therefore, we say device number 1 is sourcing the current, and device number 2 is sinking the current.
35
Okay, what if the current is flowing from device number two to device number one?
36
In this case, we say device number two is sourcing the current, and device number one is sinking the current.
37
In every situation where you have a current flow between two devices, one of the devices will be sourcing and the other will be sinking.
38
PLC vendors manufacture both sinking and sourcing digital input modules.
39
Let's explore what they are and how they differ.
40
Remember what we discussed earlier, it's all about the direction of conventional current flow.
41
Let's have a look at two devices with current flowing between them.
42
One device is a PLC input module, and the second device is a push -button switch.
43
Based on the connection polarity, the syncing module will have the current flowing into it from the switch.
44
Ok, let's do that again, but this time our PLC input module will be a sourcing module.
45
Based on the connection polarity, the sourcing module will have the current flowing out of it.
46
Current can flow in either direction through a push -button switch because it is a passive device and not polarity -dependent.
47
There are many active digital input devices used in industry today that are polarity -dependent.
48
They must be wired correctly or they will not work at all.
49
These active devices will be labeled as either syncing or sourcing.
50
You can learn more about active sensors in our other videos.
51
We'll direct you there at the end of this video.
52
If you recall, earlier we said that when there are two devices with current flowing between them, one device will be sourcing and one will be syncing.
53
If the input device is a sourcing type, the PLC input module must be a syncing type.
54
If the input device is a syncing type, the PLC input module must be a sourcing type.
55
Adding confusion to already murky concepts,
56
some vendors refer to syncing and sourcing input devices as NPN and PNP.
57
You can learn more about NPN and PNP in our other videos.
58
We'll direct you there at the end of this video.
59
Here's something to remember.
60
An NPN device is a syncing device.
61
A PNP device is a sourcing device.
62
The Siemens Digital Input Module 6ES7521 -1BH50 -0AA0 is a sourcing type.
63
If you want to order this PLC module to use in your project, you can find the link in the video description.
64
Let's connect a push -button switch and a syncing proximity sensor to two of the inputs.
65
The current is flowing out of the PLC module because it is a sourcing type.
66
Let's have a look at a syncing module.
67
The Phoenix Contact Digital Input Module AXLSEDI16 -1 is a syncing type.
68
You can find the link to order this PLC module in the video description as well.
69
Let's connect a push -button switch and a sourcing proximity sensor to two of the inputs.
70
The current is flowing into the PLC module because it is a syncing type.
71
If you want to learn more, you might want to review two of our other videos called
72
How to Wire Discrete DC Sensors to PLC Part 2 and What is a Transistor Working Principles.
73
You can find the links to these videos in the description.
74
Ok, let's review what we've covered in this video.
75
A digital input module will detect one of the two possible conditions of an input device, open or closed.
76
Digital input modules detect either a no voltage or voltage condition at the input.
77
A sinking input module will have the current flowing into it.
78
A sourcing input module will have the current flowing out of it.
79
PLC vendors offer both syncing and sourcing digital input modules.
80
An NPN device is a syncing device.
81
A PNP device is a sourcing device.
82
Want to learn PLC programming in an easy -to -understand format
83
and take your career to the next level? head on over to realpars .com

このレッスンの語彙とスピーキングのポイント

このスピーキングレッスンは、動画「Sinking and Sourcing PLC Inputs Explained」を教材にしています。 繰り返し出てくる語は次のとおりです:input, device, module, current, sourcing。 この動画には、シャドーイング用の文が83文、単語が1146語あります。 音声の長さは8:30です。 話す速さは1分あたり約135語で安定しており、シャドーイングしやすいペースです。 英語の頻出3,000語に含まれる単語は74%だけなので、語彙は難しめです。

この動画の重要語彙

動画に出てくる覚えておきたい単語15語を、発音と意味つきで紹介します。

単語発音意味
module 名詞/ˈmɑd͡ʒul/モジュール
sink 動詞/ˈsɪŋk/沈む
voltage 名詞/ˈvəʊltɪd͡ʒ/電圧
detect 動詞/dɪˈtɛkt/検出する, 見付ける
connect 動詞/kəˈnɛkt/繋げる
sensor 名詞/ˈsɛn.sɚ/センサー, センサ
vendor 名詞/ˈvɛn.dɚ/売り手, 販売者
terminal 名詞/ˈtɚmɪnəl/ターミナル, エアターミナル
dependent 形容詞/dɪˈpɛndənt/次第, 依存する
format 名詞/ˈfɔːɹ.mæt/書式, フォーマット
refer 動詞/ɹɪˈfɜː/問い合わせる
label 名詞/ˈleɪ.bəl/荷札, 貼り札
wire 名詞/ˈwaɪɚ/針金, 線
recall 動詞/ɹɪˈkɔl/呼び返す
explore 動詞/ɪkˈsploɹ/探検する

繰り返し練習したい文

動画に出てくる短く完結した文です。日常会話でそのまま使えます。

  • We'll show you more examples later.
  • Let's explore what they are and how they differ.
  • Let's have a look at a syncing module.

注意したい発音

話し手はwe'll, they're, we'reなど、短縮形や弱形を6回使っています。聞こえたとおりの短い形で発音しましょう。

  • 「sh」と「zh」の音: conventional /kənˈvɛnʃənl̩/, confusion /kənˈfjuːʒən/, misconception /ˌmɪs.kənˈsɛp.ʃən/
  • 長い単語(アクセントの位置に注意): proximity /pɹɒkˈsɪm.ɪ.ti/, polarity /pəˈlæɹɪti/, misconception /ˌmɪs.kənˈsɛp.ʃən/

日本語話者が苦手な音:

  • /r/ と /l/ の区別 — /l/ は舌先を歯茎につけ、/r/ はどこにもつけない: recall /ɹɪˈkɔl/, explore /ɪkˈsploɹ/, correctly /kəˈɹɛk(t).li/, polarity /pəˈlæɹɪti/
  • /v/ — /b/ にならないように、上の歯を下唇に当てる: voltage /ˈvəʊltɪd͡ʒ/, vendor /ˈvɛn.dɚ/, conventional /kənˈvɛnʃənl̩/, passive /ˈpæs.ɪv/, volt /vəʊlt/
  • /f/ — 「フ」ではなく、上の歯と下唇で出す: format /ˈfɔːɹ.mæt/, refer /ɹɪˈfɜː/, define /dɪˈfaɪn/, confusion /kənˈfjuːʒən/, differ /ˈdɪfɚ/

この動画での練習方法

  1. まず声を出さずに動画を最後まで聞き、知らない単語をメモします。
  2. 通常の速度で一文ずつシャドーイングし、話し手のリズムに合うまで繰り返します。
  3. 自分の声を録音して元の音声と比べます。module, sink, voltageなどの単語に特に注意しましょう。

シャドーイングとは?英語上達に効果的な理由

シャドーイング(Shadowing)は、もともとプロの通訳者養成プログラムで開発された言語学習法で、多言語習得者として知られるDr. Alexander Arguelles によって広く普及されました。方法はシンプルですが非常に効果的:ネイティブスピーカーの英語を聞きながら、1〜2秒の遅延で声に出してすぐに繰り返す——まるで「影(shadow)」のように話者を追いかけます。文法ドリルや受動的なリスニングと異なり、シャドーイングは脳と口の筋肉が同時にリアルタイムで英語を処理・再現することを強制します。研究により、発音精度、抑揚、リズム、連音、リスニング力、そして会話の流暢さが大幅に向上することが確認されています。IELTSスピーキング対策や自然な英語コミュニケーションを目指す方に特におすすめです。

シャドーイングのやり方: ステップ別の完全ガイドを読む →