In this video, we're going to talk about syncing and sourcing PLC digital input modules and how they're connected to field devices.
2
We will be using a Siemens digital input module with this part number.
3
If you want to order this module online, you can head on over to the RealPars Marketplace or simply click on this link here.
4
The two types of PLC input modules are digital and analog.
5
A digital input module accepts inputs from digital devices such as switches and proximity sensors.
6
The input module will detect one of the two possible conditions of an input device, open or closed.
7
For example, a push -button switch is a digital device and can either be open or closed.
8
We will examine how the input module detects the input device condition later in this video.
9
The focus of our video is on digital input modules.
10
Okay, let's go.
11
As we said earlier, a digital input module will detect one of the two possible conditions of an input device, open or closed.
12
So, the question is, how does the input module know if the input device is open or closed?
13
All we need to do is construct a closed circuit containing the input device,
14
the PLC input module, and a 24 volt DC power supply.
15
If the switch is open, there is 0 volts at the module input terminal.
16
If the switch is closed, there is a positive 24 volts at the module input terminal.
17
The input module will detect either a no voltage or voltage condition at the input.
18
These voltage conditions represent the open or closed conditions of the switch.
19
These voltage or non -voltage conditions are represented by ones and zeros in the PLC memory.
20
Every input device is connected the same way.
21
If you have a 64 input module, it's possible to have 64 separate circuits.
22
We'll show you more examples later.
23
Alright, now that we know how the digital input module determines the input device condition,
24
let's talk about the current flow between the power supply and the input module.
25
There is a current flow, but it is very small and usually under 10 milliamps.
26
Notice in our example that the current is flowing into the PLC module.
27
Depending on the type of PLC input module and how it's connected with the input device, the current could flow in or out of the module.
28
That's where the terms sinking and sourcing come into the picture.
29
Let's spend some time clearing up any misconceptions you might have about these terms.
30
When we talk about sinking and sourcing, it's all about defining the direction of conventional current flow between two devices.
31
Think of it this way, current is flowing between device number 1 and device number 2.
32
Ask yourself, which direction is the current flowing?
33
The current is flowing from device number 1 to device number 2.
34
Therefore, we say device number 1 is sourcing the current, and device number 2 is sinking the current.
35
Okay, what if the current is flowing from device number two to device number one?
36
In this case, we say device number two is sourcing the current, and device number one is sinking the current.
37
In every situation where you have a current flow between two devices, one of the devices will be sourcing and the other will be sinking.
38
PLC vendors manufacture both sinking and sourcing digital input modules.
39
Let's explore what they are and how they differ.
40
Remember what we discussed earlier, it's all about the direction of conventional current flow.
41
Let's have a look at two devices with current flowing between them.
42
One device is a PLC input module, and the second device is a push -button switch.
43
Based on the connection polarity, the syncing module will have the current flowing into it from the switch.
44
Ok, let's do that again, but this time our PLC input module will be a sourcing module.
45
Based on the connection polarity, the sourcing module will have the current flowing out of it.
46
Current can flow in either direction through a push -button switch because it is a passive device and not polarity -dependent.
47
There are many active digital input devices used in industry today that are polarity -dependent.
48
They must be wired correctly or they will not work at all.
49
These active devices will be labeled as either syncing or sourcing.
50
You can learn more about active sensors in our other videos.
51
We'll direct you there at the end of this video.
52
If you recall, earlier we said that when there are two devices with current flowing between them, one device will be sourcing and one will be syncing.
53
If the input device is a sourcing type, the PLC input module must be a syncing type.
54
If the input device is a syncing type, the PLC input module must be a sourcing type.
55
Adding confusion to already murky concepts,
56
some vendors refer to syncing and sourcing input devices as NPN and PNP.
57
You can learn more about NPN and PNP in our other videos.
58
We'll direct you there at the end of this video.
59
Here's something to remember.
60
An NPN device is a syncing device.
61
A PNP device is a sourcing device.
62
The Siemens Digital Input Module 6ES7521 -1BH50 -0AA0 is a sourcing type.
63
If you want to order this PLC module to use in your project, you can find the link in the video description.
64
Let's connect a push -button switch and a syncing proximity sensor to two of the inputs.
65
The current is flowing out of the PLC module because it is a sourcing type.
66
Let's have a look at a syncing module.
67
The Phoenix Contact Digital Input Module AXLSEDI16 -1 is a syncing type.
68
You can find the link to order this PLC module in the video description as well.
69
Let's connect a push -button switch and a sourcing proximity sensor to two of the inputs.
70
The current is flowing into the PLC module because it is a syncing type.
71
If you want to learn more, you might want to review two of our other videos called
72
How to Wire Discrete DC Sensors to PLC Part 2 and What is a Transistor Working Principles.
73
You can find the links to these videos in the description.
74
Ok, let's review what we've covered in this video.
75
A digital input module will detect one of the two possible conditions of an input device, open or closed.
76
Digital input modules detect either a no voltage or voltage condition at the input.
77
A sinking input module will have the current flowing into it.
78
A sourcing input module will have the current flowing out of it.
79
PLC vendors offer both syncing and sourcing digital input modules.
80
An NPN device is a syncing device.
81
A PNP device is a sourcing device.
82
Want to learn PLC programming in an easy -to -understand format
83
and take your career to the next level? head on over to realpars .com

Từ vựng và ghi chú luyện nói cho bài học này

Bài luyện nói này dựa trên video “Sinking and Sourcing PLC Inputs Explained”. Những từ được nhắc lại nhiều nhất trong bài: input, device, module, current, sourcing. Video này có 83 câu và 1146 từ để luyện shadowing. Phần lời nói dài 8:30. Người nói giữ tốc độ đều, khoảng 135 từ mỗi phút, vừa sức để nói đuổi theo. Chỉ 74% số từ nằm trong 3.000 từ tiếng Anh thông dụng nhất, nên từ vựng khá khó.

Từ vựng quan trọng trong video

15 từ đáng học trong video, kèm phiên âm và nghĩa:

TừPhiên âmNghĩa
module danh từ/ˈmɑd͡ʒul/mô-đun, bộ phận rời
sink động từ/ˈsɪŋk/chìm
voltage danh từ/ˈvəʊltɪd͡ʒ/điện áp, hiệu điện thế
detect động từ/dɪˈtɛkt/phát hiện, dò ra
connect động từ/kəˈnɛkt/nối
sensor danh từ/ˈsɛn.sɚ/cảm biến
vendor danh từ/ˈvɛn.dɚ/ngưởi bán hàng rong
terminal danh từ/ˈtɚmɪnəl/nhà ga
conventional tính từ/kənˈvɛnʃənl̩/tục lệ, lẽ thường
format danh từ/ˈfɔːɹ.mæt/khổ (sách, giấy, bìa)
label danh từ/ˈleɪ.bəl/nhãn
wire danh từ/ˈwaɪɚ/dây, dây thép
explore động từ/ɪkˈsploɹ/thám hiểm
depend động từ/dɪˈpɛnd/phụ thuộc
differ động từ/ˈdɪfɚ/khác, không giống

Những câu đáng luyện lại

Các câu ngắn, trọn ý trong video mà bạn có thể dùng lại khi giao tiếp hằng ngày:

  • We'll show you more examples later.
  • Let's explore what they are and how they differ.
  • Let's have a look at a syncing module.

Phát âm cần chú ý

Người nói dùng 6 dạng rút gọn, ví dụ we'll, they're, we're. Hãy nói theo dạng ngắn đúng như bạn nghe.

  • Âm “sh” và “zh”: conventional /kənˈvɛnʃənl̩/, confusion /kənˈfjuːʒən/, misconception /ˌmɪs.kənˈsɛp.ʃən/
  • Từ dài — đặt trọng âm cho đúng: proximity /pɹɒkˈsɪm.ɪ.ti/, polarity /pəˈlæɹɪti/, misconception /ˌmɪs.kənˈsɛp.ʃən/

Những âm người Việt thường gặp khó:

  • Cụm phụ âm cuối — đọc đủ từng âm, đừng nuốt âm cuối: sync /sɪŋk/, sink /ˈsɪŋk/, detect /dɪˈtɛkt/, connect /kəˈnɛkt/, dependent /dɪˈpɛndənt/
  • Âm /tʃ/, /dʒ/ và /ʒ/ — tiếng Việt không có, đừng đọc thành “ch” hay “gi”: module /ˈmɑd͡ʒul/, voltage /ˈvəʊltɪd͡ʒ/, confusion /kənˈfjuːʒən/
  • Âm /æ/ — mở miệng rộng hơn âm “e”: format /ˈfɔːɹ.mæt/, examine /ɪɡˈzæmɪn/, passive /ˈpæs.ɪv/, analog /ˈænəlɔɡ/, polarity /pəˈlæɹɪti/

Cách luyện với video này

  1. Nghe hết video một lần, chưa cần nói, và ghi lại những từ bạn chưa biết.
  2. Nói đuổi từng câu ở tốc độ bình thường, lặp lại mỗi câu đến khi nhịp của bạn khớp với người nói.
  3. Ghi âm giọng mình rồi so với bản gốc, chú ý các từ như module, sink, voltage.

Phương Pháp Shadowing Là Gì?

Shadowing là kỹ thuật học ngôn ngữ có cơ sở khoa học, ban đầu được phát triển cho chương trình đào tạo phiên dịch viên chuyên nghiệp và được phổ biến rộng rãi bởi nhà đa ngôn ngữ học Dr. Alexander Arguelles. Nguyên lý cốt lõi đơn giản nhưng cực kỳ hiệu quả: bạn nghe tiếng Anh của người bản xứ và lặp lại to ngay lập tức — như một "cái bóng" (shadow) đuổi theo người nói với độ trễ chỉ 1–2 giây. Khác với luyện ngữ pháp hay học từ vựng bị động, Shadowing buộc não bộ và cơ miệng phải đồng thời xử lý và tái tạo ngôn ngữ thực tế. Các nghiên cứu khoa học xác nhận phương pháp này cải thiện đáng kể phát âm, ngữ điệu, nhịp điệu, nối âm, kỹ năng nghe và độ lưu loát khi nói — đặc biệt hiệu quả cho người luyện IELTS Speaking và muốn giao tiếp tiếng Anh tự nhiên như người bản ngữ.

Phương pháp shadowing: đọc hướng dẫn từng bước đầy đủ →